Super 1750-1800 MoSi2 Heating Elements for High Temp Furnaces

$249.13

Resistivity of MoSi 2 (Molybdenum Disilicide) heating element rises dramatically when temperature rises. Power output is less than 35% of the max. output at 300 C . Resistance of a MoSi 2 heating element does not change under normal use, and you can mix new and old elements together. Generally a separator should be placed in between two shanks of heating element when installing the heating elements in the furnace.

Product total
Options total
Grand total
SKU: HEMo Category:

Description

Resistivity of MoSi2 (Molybdenum Disilicide) heating element rises dramatically when temperature rises. Power output is less than 35% of the max. output at 300C. Resistance of a MoSi2heating element does not change under normal use, and you can mix new and old elements together.

Generally a separator should be placed in between two shanks of heating element when installing the heating elements in the furnace. Please make sure the width of the separator matches the space of the heating element. If the separator is too big it may break the heating element during installation.

 

Comparison

Furnace
Element
Heating Element Dimensions
(D1xLeXLuXA)
Updated Item No.
CF1700.6.6.6 / GCF1700.6.6.6HEMo1750 7x30x3607x140x220x30HEMo1750.7.30.360
CF1700.12.8.8/ GCF1700.12.8.8HEMo1750 30×4107x190x220x30HEMo1750.30.410
CF1700.16.12.12 / GCF1700.16.12.12HEMo1750 40×5507x290x260x40HEMo1750.40.550
CF1800.7.6.6 / TF1800.80HEMo1750 6x30x3606×140×220×30HEMo1750.6.30.360
TF1700.60.1000/ TFM2.1700.60 / TFM2.1700.80 / TFM3.1700.60 / TFM3.1700.80 /HEMo1800 30×3407×120×220×30HEMo1800.30.340
TF1700.100 / TFM2.1700.100HEMo1800 30×3907×170×220×30HEMo1800.30.390

Furnace
Element
Heating Element Dimensions
(D1xLeXLuXA)
Updated Item No.
CF1700.6.6.6 / GCF1700.6.6.6HEMo1750 7x30x3607x140x220x30HEMo1750.7.30.360
CF1700.12.8.8/ GCF1700.12.8.8HEMo1750 30x4107x190x220x30HEMo1750.30.410
CF1700.16.12.12 / GCF1700.16.12.12HEMo1750 40x5507x290x260x40HEMo1750.40.550
CF1800.7.6.6 / TF1800.80HEMo1750 6x30x3606×140×220×30HEMo1750.6.30.360
TF1700.60.1000/ TFM2.1700.60 / TFM2.1700.80 / TFM3.1700.60 / TFM3.1700.80 /HEMo1800 30x3407×120×220×30HEMo1800.30.340
TF1700.100 / TFM2.1700.100HEMo1800 30x3907×170×220×30HEMo1800.30.390
Client Success Stories

Our Customers Know The Difference.

Our clients look to us to provide reliable and efficient solutions.

★★★★★

SafeLeaf has always been great at sourcing our unique needs, Sean and the team are awesome.

Brent
Brent
Operations Manager
★★★★★

The team at Safe Leaf is very knowledgeable and helpful. I can't recommend them enough if you're in this space and need someone you can trust to help you solve whatever your problem is.

Lincoln Johnson
Lincoln
CEO/CTO — BC Extraction Facilty
★★★★★

Safe Leaf came through for us in the design and build of our extraction facility. I couldn't have asked for a better quality service or source of knowledge and insight.

Mike Hodgson
Mike H
Extraction Facility Operator
Common Questions

Frequently
Asked.

SafeLeaf.ca carries a broad range of extraction and post-processing equipment including closed-loop hydrocarbon systems, CO₂ extractors, ethanol processors, rotary evaporators, falling film evaporators, wiped film distillation units, freeze dryers, vacuum ovens, and ancillary equipment. Browse the full catalogue or contact us for specific requirements.
Our primary market is Canadian processors. Some equipment can be sourced or referred for US-based operations, but regulatory and shipping considerations apply. Contact us to discuss your specific situation.
Yes. SafeLeaf.ca supports projects well beyond equipment sales, including planning, technical consulting, installation support, commissioning guidance, and broader turnkey implementation strategy.
Yes. Financing and leasing options may be available through partner channels, depending on the equipment package, customer profile, and project scope. This can make turnkey deployment much more accessible.
The best first step is a consultation. From there, SafeLeaf.ca can help define your extraction goals, recommend an appropriate workflow, identify compliance considerations, and shape a phased implementation plan.