NSF Certified 6 Ft Class II Type A2 Biosafety Cabinet

$13,347.36

A biosafety cabinet , also called a biological safety cabinet or microbiological safety cabinetis an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level. The primary purpose of a BSC is to serve as a means to protect the laboratory worker and the surrounding environment from pathogens. All exhaust air is HEPA-filtered as it exits the biosafety cabinet, removing harmful bacteria and viruses.

Product total
Options total
Grand total
SKU: BC-6F.110 Category:

Description

 

A biosafety cabinet, also called a biological safety cabinet or microbiological safety cabinetis an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level.

The primary purpose of a BSC is to serve as a means to protect the laboratory worker and the surrounding environment from pathogens. All exhaust air is HEPA-filtered as it exits the biosafety cabinet, removing harmful bacteria and viruses. This is in contrast to a laminar flow clean bench, which blows unfiltered exhaust air towards the user and is not safe for work with pathogenic agents. Neither are most BSCs safe for use as fume hoods. Likewise, a fume hood fails to provide the environmental protection that HEPA filtration in a BSC would provide. However, most classes of BSCs have a secondary purpose to maintain the sterility of materials inside (the “product”).

Class I cabinets provide personnel and environmental protection but no product protection. In fact, the inward flow of air can contribute to contamination of samples. Inward airflow is maintained at a minimum velocity of 75 ft/min(0.38 m/s). These BSCs are commonly used to enclose specific equipment (e.g. centrifuges) or procedures (e.g. aerating cultures) that potentially generate aerosols. BSCs of this class are either ducted (connected to the building exhaust system) or unducted (recirculating filtered exhaust back into the laboratory.

Class II cabinets provide both kinds of protection (of the samples and of the environment) since makeup air is also HEPA-filtered. There are five types: Type A1 (formerly A), Type A2 (formerly A/B3), Type B1, Type B2 and Type C1. Each type’s requirements are defined by NSF International Standard 49, which in 2002 reclassified A/B3 cabinets (classified under the latter type if connected to an exhaust duct) as Type A2, and added the Type C1 in the 2016 standard. About 90% of all biosafety cabinets installed are Type A2 cabinets.

Source: Wikipedia

 

 

Ai Class II Type A2 biosafety cabinet features

  • NSF certified
  • Great for COVID-19 specimen handling
  • Motorized front glass viewing window with optional foot switch
  • Dual HEPA filters with life indicator
  • UV light life indicator
  • Waterproof in-chamber power sockets
  • Large LCD display
  • Easy-to-clean stainless steel chamber
  • Special treated unit housing with anti-mold and antiseptic coating
  • Auto start and stop function (e.g. UV lights)
  • Automatic flow speed adjustment
  • Pneumatic front panel supports for easy maintenance

 

Caution! Installation requires a forklift or a crane.

Attention! Steps before and after using the unit.

  • Step 1: Fully close the front glass panel, turn on UV light for 30 mins (you can use the timer setting). Users should leave the room during this disinfection period.
  • Step 2. Raise the glass panel to recommended opening height, turn on air circulation for 10 minutes.
  • After operation is done, fully close the glass panel and turn on UV light for another 30 minutes for decontamination.

IMPORTANT GUIDELINES USING A BSC

  • No flammable and explosive substances (Building up of flammable material may cause an internal fire or explosion)
  • No volatile chemicals (May cause damage to HEPA filters to the point where it allows particles to leak through)
  • No toxic chemicals or materials (May reach room occupants)
  • No open flame (Will disrupts air flow patterns)
  • Minimal use (10mL or less) of decontaminant, such as 70% isopropyl or ethyl alcohol is allowed.
  • We recommend using the following for disinfecting the surfaces of a BSC, depending on the agent to be controlled: Sodium hypochlorite (bleach), Ilodophors (Wescodyne), Phenolics (Hilphene, Vespene) and Quaternary ammonium compounds (Conflikt, EndbacII)
  • If gaseous, vaporized or aerosolized chemicals must be generated in a BSC, you should assure yourself that the quantity being generated will NOT cause a flammable or toxic risk.

 

 

 

 

 

 

 

 

Optional Top Vent duct Connector (70% recirculated internally, 30% discharged from top vent)

Controller Screen



Remote Control
 

Specifications

 

 Model BC-6F
 Electrical requirements
 110V 60Hz 1-Phase 500 watts
 Chamber


 Dimensions: 67 x 23.5 x 26" (WxDxH)
 Material: 304 stainless steel
 Power outlet with cover: four, < 500 watts
 Water port x 1, stainless steel
 Gas port x 1, stainless steel
 Hanging bar: stainless steel, with 10 hooks
 Work surface:
   - Made from stainless steel
   - 29.5" ground clearance
   - Comes with handlles. Entire surface can be easily removed for cleaning
 Lights LED lights: 22W x 2, > 1000 Lux
 UV lights: 30W (Germicidal UV lamp, emission 253.7 nanometers)
    * UV lights available only when front glass panel is fully closed.
    * Recommended replacement interval: 600 hours
 Air flow
 Volume
    
Inflow: 825 CFM (Cubic Feet per Minute)
     Downflow: 710 CFM
     Exhaust: 485 CFM
 Speed
     Inflow: 100-110 FPM (Feet per Minute)
     Downflow: 60-70 FPM
 * 70% recirculated internally, 30% discharged from top vent
 * Air circulation available only when front glass panel is open
 Top clearance 12" (recommended)
 HEPA (High-Efficiency
   Particulate Air) filter
 Two, with 99.999% efficiency at 0.3 μm diameter
 Filter hour indicator and life bar on controller
 * Recommended replacement interval: 4,000 hours
 Front safety panel
 Material: tempered safety glass (thickness > 5mm), dual-layer, laminated, UV blocking
 Recommended opening height: 10"
 Maximum opening height: 20.5"
 Material Chamber: 304 stainless steel
 Main body: powder coated steel
 Controller LCD screen with soft touch buttons and remote control
 Noise < 65 dB(A)
 Casters Four, with stationable feet
 Weight & dimensions 
 820 Lbs (unit), 952 Lbs (shipping)
 Fully assembled: 73.5 x 30.5 x 90.5" (WxDxH)
 Without stand: 73.5 x 30.5 x 63.5” (WxDxH)
 Shipping: 79.5 x 42.5 x 75" (WxDxH)
 Safety Abnormal airflow alarm
 Filter replacement alarm
 Front glass panel unsafe height
 Compliance NSF/ANSI 49 (C0559576)
 Warranty One year
Standard Packages

Standard package

 

 Part description

 Quantity

Part image

 Ai 6 Ft Biosafety Cabinet
1 pc

 Detachable armrest4 pcs
 On/off foot switch1 pc
 Remote1 pc
 Bottom drain port assembly
1 pc
 
 Backup UV light tube1 pc 
 Hex wrench1 pc
 Front glass panel motor adjusting tool, plastic
1 pc
 Fuse (for glass panel control board)
9 pcs 
 Hex bolt
7 pcs
 Big, smaller and lock washers7 sets 
 Standard 110V Power Cord
1 pc
Stand Assembly (Set)
• Legs (2 wheels casters/leg) x 2
• Leg back panel x 1
3 pcs

 User's manual1 pc

Client Success Stories

Our Customers Know The Difference.

Our clients look to us to provide reliable and efficient solutions.

★★★★★

SafeLeaf has always been great at sourcing our unique needs, Sean and the team are awesome.

Brent
Brent
Operations Manager
★★★★★

The team at Safe Leaf is very knowledgeable and helpful. I can't recommend them enough if you're in this space and need someone you can trust to help you solve whatever your problem is.

Lincoln Johnson
Lincoln
CEO/CTO — BC Extraction Facilty
★★★★★

Safe Leaf came through for us in the design and build of our extraction facility. I couldn't have asked for a better quality service or source of knowledge and insight.

Mike Hodgson
Mike H
Extraction Facility Operator
Common Questions

Frequently
Asked.

SafeLeaf.ca carries a broad range of extraction and post-processing equipment including closed-loop hydrocarbon systems, CO₂ extractors, ethanol processors, rotary evaporators, falling film evaporators, wiped film distillation units, freeze dryers, vacuum ovens, and ancillary equipment. Browse the full catalogue or contact us for specific requirements.
Our primary market is Canadian processors. Some equipment can be sourced or referred for US-based operations, but regulatory and shipping considerations apply. Contact us to discuss your specific situation.
Yes. SafeLeaf.ca supports projects well beyond equipment sales, including planning, technical consulting, installation support, commissioning guidance, and broader turnkey implementation strategy.
Yes. Financing and leasing options may be available through partner channels, depending on the equipment package, customer profile, and project scope. This can make turnkey deployment much more accessible.
The best first step is a consultation. From there, SafeLeaf.ca can help define your extraction goals, recommend an appropriate workflow, identify compliance considerations, and shape a phased implementation plan.